Estimation of R404A Refrigerant Cooling Load and System Efficiency of a Small-Scale Cold Box for Strenghten The Fisheries Cold Chain in Timbolsloko, Demak

Authors

  • Hanityo Adi Nugroho Department of Marine Science, Faculty of Science and Agroculture Technology, Universitas Muhammadiyah Semarang
  • Samsudi R Department of Mechanical Engineering, Faculty of Engineering and Computer Science, Universitas Muhammadiyah Semarang
  • Rubijanto JP Department of Mechanical Engineering, Faculty of Engineering and Computer Science, Universitas Muhammadiyah Semarang
  • M. Ahnaf F Department of Mechanical Engineering, Faculty of Engineering and Computer Science, Universitas Muhammadiyah Semarang
  • Aulia SS Department of Marine Science, Faculty of Science and Agroculture Technology, Universitas Muhammadiyah Semarang
  • Aditano YR Department of Marine Science, Faculty of Science and Agroculture Technology, Universitas Muhammadiyah Semarang

DOI:

https://doi.org/10.26740/vubeta.v3i2.40752

Keywords:

Cooling Load, Refrigeration System, Energy Efficiency, R404A Refrigerant, Fishing Vessel

Abstract

The cooling system of the fishing boat is extremely crucial in maintaining the quality of the catch during storage. In this study, the system performance and cooling load are analyzed in a box of dimensions 1.8 m × 2.4 m × 1.2 m with R404A refrigerant at an evaporation temperature of -21.8°C and a condensation temperature of 37.6°C. Total daily cooling load is 15.504 kWh, which includes heat transmission load of 5.653 kWh, product load of 6.656 kWh, internal load of 0.542 kWh, equipment load of 1.61 kWh, and infiltration load of 1.043 kWh. System performance by pressure-enthalpy (P-h) analysis provides actual Coefficient of Performance (COP) as 4 with 94% refrigeration efficiency. The 100 mm polyurethane insulation utilized are enhance energy efficiency and environmental sustainability. This cooling system design was found to be optimal for maintaining the box temperature at -20°C with high efficiency, serving to benefit the small-scale fisheries sector under tropical conditions.

Author Biographies

Hanityo Adi Nugroho, Department of Marine Science, Faculty of Science and Agroculture Technology, Universitas Muhammadiyah Semarang

Hanityo Adi Nugroho        is a lecturer in the Department of Marine Science, Universitas Muhammadiyah Semarang, Indonesia. He is received the BSc from the University of Diponegoro Semarang (UNDIP Semarang) in Fisheries Resources Utillization, Management, and Technology, Semarang in 2014. He is received the M.Si from the University of Diponegoro Semarang (UNDIP Semarang) in Marine Science, Semarang in 2019. He is mainly research in the marine instrumentation and control. He can be contacted at email: hanityoadi@unimus.ac.id.

Samsudi R, Department of Mechanical Engineering, Faculty of Engineering and Computer Science, Universitas Muhammadiyah Semarang

Department of Mechanical Engineering, Faculty of Engineering and Computer Science, Universitas Muhammadiyah Semarang

Rubijanto JP, Department of Mechanical Engineering, Faculty of Engineering and Computer Science, Universitas Muhammadiyah Semarang

Department of Mechanical Engineering, Faculty of Engineering and Computer Science, Universitas Muhammadiyah Semarang

M. Ahnaf F, Department of Mechanical Engineering, Faculty of Engineering and Computer Science, Universitas Muhammadiyah Semarang

Department of Mechanical Engineering, Faculty of Engineering and Computer Science, Universitas Muhammadiyah Semarang

Aulia SS, Department of Marine Science, Faculty of Science and Agroculture Technology, Universitas Muhammadiyah Semarang

 Department of Marine Science, Faculty of Science and Agroculture Technology, Universitas Muhammadiyah Semarang

Aditano YR, Department of Marine Science, Faculty of Science and Agroculture Technology, Universitas Muhammadiyah Semarang

 Department of Marine Science, Faculty of Science and Agroculture Technology, Universitas Muhammadiyah Semarang

References

[1] M. Ajuji, M. Dawaki, A. Mohammed, and A. Ahmad4, “Estimating Residential Natural Gas Demand and Consumption: A Hybrid Ensemble Machine Learning Approach,” Vokasi UNESA Bull. Eng. Technol. Appl. Sci., vol. 2, no. 3, pp. 549–557, 2025. https://doi.org/10.26740/vubeta.v2i3.40135.

[2] Anderson J., Smith R., & Taylor M., “Optimizing Refrigeration Systems for Food Quality and Cost Efficiency,” Journal of Food Engineering, vol. 320, 104756, 2023.

[3] W. Aribowo, L. Abualigah, D. Oliva, T. Mzili, S. Aliyu, and H. A. Shehadeh, “Frilled Lizard Optimization to Optimize Parameters Proportional Integral Derivative of DC Motor,” Vokasi UNESA Bull. Eng. Technol. Appl. Sci., vol. 1, no. 1, pp. 14–21, Aug. 2024. https://doi.org/10.26740/vubeta.v1i1.33973.

[4] Atici Ö. A. and Özkan D. B., “Experimental and Theoretical Investigation of Thermal Parameters Influencing the Freezing Process of Ice Cream,” Applied Sciences (Switzerland), vol. 14, no. 14, 2024. https://doi.org/10.3390/app14146194.

[5] Biçen E., and Arabacı, S. K., “Energy And Exergy Evaluation Of R404A And R290 In A Shelf-Cooled Commercial Vertical Deep Freezer,” Applied Thermal Engineering, vol. 278, 2025. https://doi.org/10.1016/j.applthermaleng.2025.127287.

[6] Cabello R., Sánchez D., Llopis R., Andreu-Nacher A., and Calleja-Anta D., “Energy Impact Of The Internal Heat Exchanger In A Horizontal Freezing Cabinet. Experimental Evaluation With The R404A Low-GWP Alternatives R454C, R455A, R468A, R290 And R1270,” International Journal of Refrigeration, vol. 137, pp. 22–33. https://doi.org/10.1016/j.ijrefrig.2022.02.007.

[7] Cabello R., Sánchez D., Llopis R., Nebot-Andrés L., and Calleja-Anta D., “Energy Evaluation Of A Low-Temperature Commercial Refrigeration Plant Working With The New Low-GWP Blend R468A As A Drop-In Of R404A,” International Journal of Refrigeration, vol. 127, pp. 1–11, 2021. https://doi.org/10.1016/j.ijrefrig.2021.01.012.

[8] Chen M., Yang Q., Shi B., Chen X., Chi W., Liu G., Zhao Y., and Li L., “Performance Comparison Of Ultra-Low Temperature Cascade Refrigeration Cycles Using R717/R170, R717/R41 And R717/R1150 To Replace R404A/R23,” Thermal Science and Engineering Progress, vol. 44, 2023. https://doi.org/10.1016/j.tsep.2023.102048.

[9] Chen L., Zhang H., & Li J., “Advancements in Energy-Efficient Cooling Technologies for Industrial Applications,” Energy Reports, vol. 10, 217–230, 2024. https://doi.org/10.1016/j.egyr.2024.01.010.

[10] Cogné C., Andrieu J., Laurent P., Besson A., and Nocquet J., “Experimental Data And Modeling Of Thermal Properties Of Ice Creams,” Journal of Food Engineering, vol. 58, no. 4, pp. 331–341, 2023. https://doi.org/10.1016/S0260-8774(02)00396-5.

[11] Devecioglu A. G., and Oruç, V., “On The Satisfaction Of EU F-Gas Regulation Using R455A As An Alternative To R404A In Refrigeration Systems,” Materials Today: Proceedings, vol. 52, pp. 1865–1869, 2021. https://doi.org/10.1016/j.matpr.2021.11.506.

[12] Devecioğlu A. G., & Oruç V., “The Thermodynamic And Environmental Analysis Of A Variable-Speed R404A Refrigeration System Using R455A,” Thermal Science and Engineering Progress, vol. 56, 2024. https://doi.org/10.1016/j.tsep.2024.103083.

[13] Eliasson S., Ragnarsson S. O., Arason S., Margeirsson B., & Palsson O. P., “Onboard Pre-Chilling Of Ungutted And Gutted Atlantic Cod In Different Cooling Media -Temperature Measurements And Analytical Modelling,” International Journal of Refrigeration, vol. 132, pp. 72–81. https://doi.org/10.1016/j.ijrefrig.2021.08.027.

[14] García R., and Martínez F., “Refrigerant Alternatives for Industrial Refrigeration: A Sustainability Perspective,” Applied Thermal Engineering, vol. 220, 119224, 2023. https://doi.org/10.1016/j.applthermaleng.2023.119224.

[15] Giménez-Prades P., Navarro-Esbrí J., Udroiu C. M., and Mota-Babiloni A., “Experimental Retrofit of an R404A/R23 Ultra-low Temperature Freezer Using R448A and Electronic Expansion Valves,” International Journal of Refrigeration, vol. 171, pp. 217–227, 2025. https://doi.org/10.1016/j.ijrefrig.2025.01.017.

[16] Graham J., Johnston W.A., Nicholson F.J., “Ice in fisheries,” FAO Fisheries Technical Paper. No. 331. FAO, Rome 75. Chpt. 3. ISBN 92-5-103280-7, 1992.

[17] Hassan M., El-Sayed A., & Omar M., “Cooling Load Analysis for Industrial Refrigeration Systems,” International Journal of Refrigeration, vol. 146, pp. 245–256, 2024. https://doi.org/10.1016/j.ijrefrig.2024.01.012.

[18] Kumar R., Singh, P., & Yadav S., “Comparative Analysis of Refrigeration Systems Using Eco-Friendly Refrigerants,” Journal of Cleaner Production, vol. 394, 136188, 2023. https://doi.org/10.1016/j.jclepro.2023.136188.

[19] Lee M., Shin M., and Cho H., “Investigation On Absorption Separation Characteristics Of R134a, R1234yf, R22, R410A, And R404A Using MWCNT-[HMIM][Tf2N] Io Nano Fluid,” Thermal Science and Engineering Progress, vol. 47, 2024. https://doi.org/10.1016/j.tsep.2023.102362.

[20] Liang K., Zhou Y., and Wang X., “Impact of Transportation Refrigeration on Food Preservation and Energy Efficiency,” Sustainable Energy Technologies and Assessments, vol. 59, 103873, 2023. https://doi.org/10.1016/j.seta.2023.103873.

[21] Li Y. C. M. and Chen Y. H. A., “Assessing The Thermal Performance Of Three Cold Energy Storage Materials With Low Eutectic Temperature for the Food Cold Chain,” Energy, vol. 115, pp. 238–256, 2016. https://doi.org/10.1016/j.energy.2016.08.106.

[22] Lind I., “The Measurement and Prediction of Thermal Properties of Food during Freezing and Thawing: A Review with Particular Reference to Meat and Dough,” Journal of Food Engineering, vol. 13, 1991.

[23] Lee H., and Kim S., “High-Performance Insulation Materials for Cold Storage Applications,” Construction and Building Materials, vol. 290, 124568, 2024. https://doi.org/10.1016/j.conbuildmat.2024.124568.

[24] Mannarini G., Salinas M. L., Carelli L., Petacco N., and Orović, J., “VISIR-2: Ship Weather Routing in Python,” Geoscientific Model Development, vol. 17, no. 10, 4355–4382, 2024. https://doi.org/10.5194/gmd-17-4355-2024.

[25] Oruç V., and Devecioğlu, A. G., “Experimental Investigation on the Low-GWP HFC/HFO Blends R454A And R454C In a R404A Refrigeration System,” International Journal of Refrigeration, vol. 128, pp. 242–251, 2021. https://doi.org/10.1016/j.ijrefrig.2021.04.007.

[26] Oruç V., Devecioğlu A. G., and İlhan D. B., “Retrofit Of An Internal Heat Exchanger In A R404A Refrigeration System Using R452A: Experimental Assessment On The Energy Efficiency And CO2 Emissions,” Next Energy, vol. 3, 2024. https://doi.org/10.1016/j.nxener.2024.100107.

[27] Obais A. M., & Mukheef, A. A., “Design of a 120V, 5A SEPIC DC-DC Converter for Unipolar 120V DC Microgrid,” Vokasi Unesa Bulletin of Engineering, Technology and Applied Science, vol. 2, no. 3, pp. 655–665, 2025. https://doi.org/10.26740/vubeta.v2i3.44140.

[28] Obari J. A., Tijani A. S., Monday A, I., and Busayo H, A., “An Emission And Weight-Based Road Traffic Congestion Pricing System And Control With Consideration Of Investment Worthiness,” Vokasi Unesa Bulletin of Engineering, Technology and Applied Science, vol. 2, no. 3, pp. 401–411, 2025. https://doi.org/10.26740/vubeta.v2i3.38528.

[29] Patel D. and Mehta R., “Future Trends in Industrial Refrigeration: Energy Efficiency and Environmental Impacts,” Energy and Buildings, vol. 312, 125874, 2024. https://doi.org/10.1016/j.enbuild.2024.125874.

[30] Pérez C. and Gómez J., “Energy and Environmental Assessment of Refrigerated Transport Systems,” Renewable and Sustainable Energy Reviews, vol. 163, 112554, 2023. https://doi.org/10.1016/j.rser.2023.112554.

[31] Qian X., Zhang R., Yuan M., Zhang Q. and Jiang J., “Study On Explosion Characteristics And Self-Suppression Mechanism Of R404A Refrigerant In A Closed Container Under Oxygen-Enriched Conditions,” Case Studies in Thermal Engineering, vol. 26, 2021. https://doi.org/10.1016/j.csite.2021.101174.

[32] Roy A., and Sarkar J., “Sustainable Refrigeration Practices for Reducing Carbon Footprints in Food Supply Chains,” Journal of Sustainable Energy Systems, vol. 15, no. 2, pp. 152–170. https://doi.org/10.1007/s10499-024-10002-6.

[33] Sacasas D., Vega J., Cuevas C., Menéndez A., and Borrajo, R., “An improved approach to model compressors, condenser/gas cooler, and their control system in refrigeration systems with R404A and R744 based on physical principles,” International Journal of Refrigeration, vol. 153, pp. 127–139, 2023 https://doi.org/10.1016/j.ijrefrig.2023.06.024.

[34] Saleem A. and Kim, M. H., “Miscibility analysis of polyol-ester based oil SW32 with R404A and low-GWP refrigerant R452A,” International Journal of Refrigeration, vol. 129, pp. 22–31, 2021 https://doi.org/10.1016/j.ijrefrig.2021.05.002.

[35] Singh M., Gupta A., and Sharma, K., “Thermodynamic Analysis of Refrigeration Systems Using Advanced Exergy Methods.” Energy Conversion and Management, vol. 303, 115747, 2024. https://doi.org/10.1016/j.enconman.2024.115747.

[36] Tang, X., Wang, H., & Feng, Y., “Design and Performance Evaluation of Refrigeration Systems for Perishable Goods Transport,” International Journal of Heat and Mass Transfer, vol. 207, 125475, 2023. https://doi.org/10.1016/j.ijheatmasstransfer.2023.125475.

[37] M. Taufiqurrohman and D. Octaviani, “Portable Pico Hydro Power Plant for Power Station Charger”, Vokasi UNESA Bull. Eng. Technol. Appl. Sci., vol. 1, no. 2, pp. 1–11, 2024. https://doi.org/10.26740/vubeta.v1i2.35597.

[38] Tolstorebrov I., Eikevik T. M., and Bantle M., “Effect of low and ultra-low temperature applications during freezing and frozen storage on quality parameters for fish,” International Journal of Refrigeration, vol. 63, pp. 37–47, 2016. https://doi.org/10.1016/j.ijrefrig.2015.11.003.

[39] Wang T., Lee C., and Park J., “Thermal Analysis and Optimization of Cooling Systems in Food Storage,” Journal of Thermal Science and Engineering Applications, vol. 15, no. 4, 041010, 2023. https://doi.org/10.1115/1.4057538.

[40] A. W. Wicaksono, A. Nawawi, M. Erfin Prafitama S., Y. Herwanto, W. Aribowo, and D. Herjuno, “LoRa-based DC Motor Control and Yagi Antenna”, Vokasi UNESA Bull. Eng. Technol. Appl. Sci., vol. 1, no. 2, pp. 12–25, 2024. https://doi.org/10.26740/vubeta.v1i2.34852.

[41] Yang J., Lee D., Lee S., Han C., and Kim Y., “Condensation Heat Transfer Characteristics And Generalized Correlations of R404A, R448A, And R454C In A Plate Heat Exchanger,” International Communications in Heat and Mass Transfer, vol. 147, 2023. https://doi.org/10.1016/j.icheatmasstransfer.2023.106975.

[42] Yoon J. and Park K., “Variable Refrigerant Flow Systems for Small-Scale Industrial Applications,” Journal of Energy Systems Engineering, vol. 29, no. 3, pp. 189–202, 2023. https://doi.org/10.1016/j.energyeng.2023.123123.

[43] Zhu Z., Liu X., Wang X., and Liu B., “Enhancing The Efficiency Of Large Cold Store Refrigeration Systems Through Automated Fault Identification and Intelligent Energy Optimization,” International Journal of Refrigeration, vol. 168, pp. 411–422, 2024. https://doi.org/10.1016/j.ijrefrig.2024.09.002.

[44] Zeng M. Q., Zou L. G., Peng Z. R., Zhang X. R., and Li J., “Numerical Study Of Condensation Heat Transfer Characteristics Of R134a/R290 And R134a/R1270 Refrigerant Blends As Alternatives To Replace R404A,” Applied Thermal Engineering, vol. 243, 2024. https://doi.org/10.1016/j.applthermaleng.2024.122644.

[45] Zhang L., Yang Z., Zhai R., Lv Z., Zhang Y., and Deng Q., “Flammable Performance And Experimental Evaluation Of A New Blend As R404A Lower-GWP Alternative,” International Journal of Refrigeration, vol. 135, pp. 113–120, 2022. https://doi.org/10.1016/j.ijrefrig.2021.12.019.

[46] Zhao Y. and Liu T., "Optimization of Refrigeration System Designs for Energy Saving in Cold Chains, " Energy, vol. 278, 125762, 2023. https://doi.org/10.1016/j.energy.2023.125762.

Downloads

Published

2026-05-28

How to Cite

[1]
H. A. Nugroho, S. R, R. JP, M. A. F, A. SS, and A. YR, “Estimation of R404A Refrigerant Cooling Load and System Efficiency of a Small-Scale Cold Box for Strenghten The Fisheries Cold Chain in Timbolsloko, Demak ”, Vokasi UNESA Bull. Eng. Technol. Appl. Sci., vol. 3, no. 2, pp. 344–354, May 2026.
Abstract views: 0 , PDF Downloads: 0

Similar Articles

1 2 3 4 5 6 7 > >> 

You may also start an advanced similarity search for this article.